Common array manager.

Firmware. Firmware delivered with Sun Storage Common Array Manager software can be installed using the Install Firmware Baseline feature. However, moving from one major firmware release to another (6.x to 7.x) requires a utility specific to the array family.

Common array manager. Things To Know About Common array manager.

Sun Storage Common Array Manager: How to Save an Array Configuration for Duplication or Restoration (Doc ID 1007142.1) Last updated on JANUARY 30, 2022. Applies to: Sun Storage 6180 Array - Version Not Applicable to Not Applicable [Release N/A] Sun Storage 2510 Array - Version Not Applicable to Not Applicable [Release N/A] ——————————————————————————-Sun Storage Common Array Manager 6.8.1 Please read the following license agreement carefully. Oracle has acquired Sun Microsystems, Inc. (“Sun”), you acknowledge that in all cases where the reference is Sun, Oracle will fulfill these obligations as successor in ...Sun Storage Common Array Manager (CAM) - Version 5.0 to 5.1 [Release 5.0] Oracle Solaris on SPARC (64-bit) Oracle Solaris on SPARC (32-bit) Oracle Solaris on x86-64 (64-bit) Oracle Solaris on x86 (32-bit) Symptoms. Execution of the RunMe.bin installer, or RunMe.bin -c, on Solaris[TM] Operating System, fails with:Common Array Manager. user-lvozg Feb 12 2023. Unable to see StorageTek6410 in Oracle Java Web Console after installing Common Array Manager, but I can only see Hosts statistics such as cpu usage, local hard drive and memory usage status.

The SAS expander on the Multi-Fabric NEM is SES-2 compliant. These enclosure management features are available through the management software called the Sun Common Array Manager (CAM), which … 使用 GUI 管理阵列 《Sun Storage Common Array Manager 阵列管理指南,版本 6.9.0》 使用 sscs CLI 管理阵列 《Sun Storage Common Array Manager CLI Guide, Version 6.9.0》 故障排除信息和硬件更换过程 服务顾问,从 Sun Storage Common Array Manager GUI 启动 从固件版本 6.x 升级到 7.x “升级固件 ...

通过打开浏览器并输入下列地址,从主阵列管理服务器登录 Sun Storage Common Array Manager: https://host-name:6789. 其中,host-name 为连接到该阵列的服务器的 DNS 名称。. 在“存储系统摘要”页面中,单击“注册”并按照向导中的说明将该阵列注册到第一个服务器的 IP 地址 ... 1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user …

Select the array. Select Administration -> Manage Passwords -> Update Array Password in Array Registration Database. Leave the "New Password" and "Verify New Password" fields blank. To remove the array password on a 6130 running a firmware lower than 06.19.23.10, you can use the "clrpw" utility available here.Adding New Users and Assigning Roles. Creating Host Accounts. To use the Sun Storage Common Array Manager, users and roles must be defined on the host and assigned in the array management software. Make sure the following user names are defined on your systems: root (or an administrative user for Windows) storage.Sun Storage Common Array Manager (CAM) - Version 6.1 to 6.10 [Release 6.0]: Sun Storage Common Array Manager (CAM): Connections Refused with Error "ERR_SSL_WEAK_SERLook for the StorageTek Common Array Manager (CAM) Software release 6.1.2 or later. Using CAM With Disk Blades and Virtualized Multi-Fabric 10GbE NEM. CAM provides both a browser and command-line interface. When using the browser interface, you set up user accounts. When an authorized user logs in, information is laid out in pages.1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user …

Multiple array management<br /> Remote Proxy<br /> The remote proxy agent enables communication, equivalent to in-band management,<br /> from the full management host to the array over an out-of-band-band IP network.<br />

SANtricity or Common Array Manager report a critical fault of Host IO Card has Failed (xx.66.1150). SANtricity or Common Array Manager report a critical fault of Host IO Card is Degraded (xx.66.1300). SANtricity or Common Array Manager reports a critical fault of One or More Volumes not on their Preferred Path (xx.66.1010).

This article documents Sun Storage 2540-M2 Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose of …Sun StorageTekTM Common Array Manager CLI Quick Reference. This document lists the sscs(1M) subcommands that you can use to administer the Sun StorageTekTM 6130, 6140, 6540, 2500 Series Arrays, and FlexLine 240, 280, and 380 Systems from the command-line interface (CLI).For the Sun Storage J4000 Array Family, refer to the Sun …Sun Storage Common Array Manager (CAM) has the ability to collect support-based configuration and logs for Sun Storage 2500, 2500-M2, J4000, F5100, 6000 and Flexline Arrays. This can be performed using the Browser or CLI interface. The purpose of this document is to describe how to collect this information. If you are using a …How to Download Common Array Manager (CAM) Software and Patches [Doc ID 1296274.1] Note - Each array should be managed by one CAM management host only. Installing the management software on more than one host to manage the same array can cause discrepancies in the information reported by CAM.It is best practice to upgrade HBAs (SG-XPCIE8SAS-E-Z) to Phase 14 firmware (1.26.03 or later) before upgrading JBOD installations to Sun Storage Common Array Manager version 6.6 and above. This helps avoid issues when discovering JBODs that have SIM firmware 3A53 (J4200) or 3R53 (J4400).

Documentation. For hardware information, refer to the array's release notes and hardware installation guide. Online help and man pages are incorporated into the Sun Storage Common Array Manager software.Most people looking for Common array manager downloaded: Sun Storage Common Array Manager Online Help. Download. One Interface, Run-Anywhere Flexibility Now there's an easy way to manage your storage environment. Similar choice › Download common view exe free › Gnu common lisp 2.4.9 free download; Sun StorageTek Common Array Manager Installation Software CD 提供了三个与安装 有关的向导:. GUI (Graphical User Interface,图形用户界面)软件安装程序 - 使您可以通过图 形用户界面向导安装一系列选定的应用程序,以支持本地或远程的管理主机。. CLI (Command-Line Interface ... Sun Storage Common Array Manager does not provide an SNMP agent that can be queried using SNMP ’GET’ operations. At times, the devices themselves support SNMP ’GET’ operations although all the arrays supported by the array management software at this time do not. Instead customers typically do remote scripting using the remote CLI …Note - At the release of this document, there is currently no support for using the Common Array Manager to upgrade disk module and SAS-NEM firmware to a level that allows SAS-1 device coexistence with server modules with SAS-2 REMs.For more information on upgrading disk module and SAS-NEM firmware to a level that allows SAS-1/SAS-2 …Select the array. Select Administration -> Manage Passwords -> Update Array Password in Array Registration Database. Leave the "New Password" and "Verify New Password" fields blank. To remove the array password on a 6130 running a firmware lower than 06.19.23.10, you can use the "clrpw" utility available here.

“Related Documentation” on page vi for a list of array installation document titles. Related Documentation TABLE P-1 provides a list of documents related to the Sun Storage Common Array Manager software. TABLE P-1 Related Documentation Application Title Latest information Sun Storage Common Array Manager Software Release Notes

Common Array Manager Software Features. The Sun StorageTek Common Array Manager (CAM) software provides an easy-to-use interface from which you can configure, manage, and monitor Sun StorageTek and Sun Storage arrays.Sun Storage Common Array Manager (CAM) - Version 5.0 and later Information in this document applies to any platform. Symptoms. Common Array Manager (CAM) is generating an alarm for a fault against one of its registered arrays. CAM fails to report the appropriate description and grid code for the alarm. The details may look …iv Sun StorageTek Common Array Manager CLI Guide • September 2009 Commands Used 21 Sample Data 21 Command Sequence 21 3. Monitoring and Administration Commands for All Arrays 27 add notification 27 Synopsis 27 Description 28 Options 28 Examples 29 add registeredarray 29 Synopsis 29 Description 29 Options 30 Examples 30Jun 20, 2019 · Purpose. Sun Storage Common Array Manager (CAM) is used for managing and monitoring many Sun Storage arrays. CAM's notification capabilities include on-screen alarms and events via the BUI, and CAM can also send notifications via email or SNMP. This document covers setting up SNMP notifications from CAM. Goal. If you want to install Sun Storage Common Array Manager (CAM) in a Solaris 10 non-global zone, you first need to install Lockhart/Java Web Console in the Solaris 10 global zone, otherwise the installation of CAM fails with one or more of the following errors:Common Array Manager. 895784 Oct 22 2011 — edited Oct 22 2011. Hi Experts, I am Installing Common array manager software on sparc T5120, while installing sun java web console is missing some LION packages whether i go forward what will happen? any solution for this please guide me. Thanks, kk. Comments.Common Array Manager. 895784 Oct 22 2011 — edited Oct 22 2011. Hi Experts, I am Installing Common array manager software on sparc T5120, while installing sun java web console is missing some LION packages whether i go forward what will happen? any solution for this please guide me. Thanks, kk. Comments.Common Array Manager alarm code xx.66.1091: Battery Tray.xx.Battery.x has transitioned to an unknown state; SANtricity Storage Manager fault of BATTERY_UNKNOWN_STAT; Reference: <Document 1021057.1> Sun Storage Common Array Manager (CAM): How to Verify Critical Faults for Sun Storage 2500, 2500-M2, … Sun Storage Common Array Manager Quick Start Guide, Version 6.8.x This guide can help you with the basic steps of installing Oracle’s Sun Storage Common Array Manager software. If you are upgrading from a previous version or need additional information, see the Sun Storage Common Array Manager Software Installation and Setup Guide. The Sun Storage Common Array Manager (CAM) 6.10 release is available only for Solaris OS management hosts. CAM 6.10 for Linux and Windows hosts is in development and will be available once it is complete. Until then, continue to use CAM 6.9 for Linux and Windows, which is available from My Oracle Support (MOS) https://support.oracle.com.

1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user to root: $ su -

The intent of this document is to explain how to download Common Array Manager (CAM) and its patches from My Oracle Support (MOS) - Patches & Updates. The 3 steps are: …

Storage Common Array Manager 6.10. Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays Sun Storage 6000 Series, StorageTek 6000 Series, and FlexLine Arrays Sun Storage J4000 Series Arrays, Sun Storage F5100 Flash Array, and Sun Blade 6000 Disk Module Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays1Sun StorageTek Common Array Manager The Sun StorageTek Common Array Manager software is a key component for the initial configuration and operation of the Sun StorageTek 2500 Series Array hardware. It is installed on a management host cabled to the array via out-of-band Ethernet (cables for this connection are provided). To obtain a …Jun 20, 2019 · Purpose. Sun Storage Common Array Manager (CAM) is used for managing and monitoring many Sun Storage arrays. CAM's notification capabilities include on-screen alarms and events via the BUI, and CAM can also send notifications via email or SNMP. This document covers setting up SNMP notifications from CAM. The Sun StorageTek Common Array Manager software provides you with an easy-to-use interface to configure, manage, and monitor Sun StorageTek storage arrays. New features in Release 6.0.0: Enhancements to Auto Service Request (ASR) functionality. Support for Sun StorageTek FLX240, FLX280, and FLX380 Arrays. Sun StorageTek Common Array Manager Software Release Notes, Release 6.1: PDF: Sun StorageTek Common Array Manager Software Installation Guide, v6.1: HTML: PDF: Sun StorageTek Common Array Manager CLI Quick Reference, v6.1: PDF: Sun StorageTek Common Array Manager User Guide for the J4000 Array Family, Version …SANtricity Storage Manager - Version 10.50 and later Sun Storage Common Array Manager (CAM) - Version 5.0 and later All Platforms Goal. The purpose of this document is to provide a description of how to review the details …You’ll find the most current information about Sun StorageTek Common Array Manager software in these 6.1.1 version Release Notes, including features, release ...xii Sun StorageTek Common Array Manager Software Installation Guide • January 2007 How This Book Is Organized Chapter 1 provides an overview of the Sun StorageTek Common Array Manager software and installation process. Chapter 2 describes how to install the Common Array Manager software and the local and remote host …

The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web browser interface is the primary interface for configuring, managing, and monitoring the system. Two command-line interfaces options are also provided. 1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet n.n.n.n. 3. After logging in, switch user … Oracle’s Sun Storage Common Array Manager includes the following documentation integrated within the software: Sun Storage Common Array Manager online help Available via the “Help” button within the Sun Storage Common Array Manager browser interface. Service Advisor Provides guided, FRU-replacement procedures with system feedback for all 2. Instructions to download Common Array Manager (CAM). Method 1 - Searching with the MOS patch number: Log in to My Oracle Support. Click on the "Patches & Updates" tab on the top bar. In the "Patch Name or Number" field, enter the patch number (ie: 10272123 or 141474-01) corresponding to the CAM software or patch you want to download.Instagram:https://instagram. spanish crosswordgoogle cloud vision apapps to help save moneyorlando fl to fort lauderdale fl Sun Storage Common Array Manager software models the aggregated connections as a single, logical SAS port. The information displayed in the Access Configuration Summary only lists the connected port with the higher alphanumeric sort. For example, if Ports 0 and 2 are connected into the same expander, only Port 2 is listed. hooda math websitenorth apartments Multiple array management<br /> Remote Proxy<br /> The remote proxy agent enables communication, equivalent to in-band management,<br /> from the full management host to the array over an out-of-band-band IP network.<br /> www parkmobile Select the array. Select Administration -> Manage Passwords -> Update Array Password in Array Registration Database. Leave the "New Password" and "Verify New Password" fields blank. To remove the array password on a 6130 running a firmware lower than 06.19.23.10, you can use the "clrpw" utility available here.This document is designed to help clarify when a drive should be replaced, if this fault should be present on an array. Symptoms Include: SANtricity Storage Manager shows an alert for Impending Drive Failure Low Risk; Common Array Manager shows an alarm for Impending Drive Failure Risk Low (xx.66.1026)